GSO ISO 17179:2021

Gulf Standard   Current Edition
· Approved on 01 July 2021 ·

Stationary source emissions — Determination of the mass concentration of ammonia in flue gas — Performance characteristics of automated measuring systems

GSO ISO 17179:2021 Files

GSO ISO 17179:2021 Scope

ISO 17179:2016 specifies the fundamental structure and the most important performance characteristics of automated measuring systems for ammonia (NH3) to be used on stationary source emissions, for example, combustion plants where SNCR/SCR NOx control systems (deNOx systems) are applied. The procedures to determine the performance characteristics are also specified. Furthermore, it describes methods and equipment to determine NH3 in flue gases including the sampling system and sample gas conditioning system.

It describes extractive systems, based on direct and indirect measurement methods, and in situ systems, based on direct measurement methods, in connection with a range of analysers that operate using, for example, the following principles:

- ammonia conversion to, or reaction with NO, followed by chemiluminescence (CL) NOx difference measurement for ammonia (differential NOx);

- ammonia conversion to, or reaction with NO, followed by non-dispersive ultraviolet (NDUV) spectroscopy NOx difference measurement for ammonia (differential NOx);

- Fourier transform infrared (FTIR) spectroscopy;

- non-dispersive infrared (NDIR) spectroscopy with gas filter correlation (GFC);

- tuneable laser spectroscopy (TLS).

The method allows continuous monitoring with permanently installed measuring systems of NH3 emissions, and is applicable to measurements of NH3 in dry or wet flue gases, for process monitoring, long term monitoring of the performance of deNOx systems and/or emission monitoring.

Other equivalent instrumental methods can be used, provided they meet the minimum requirements proposed in ISO 17179:2016. The measuring system can be calibrated with certified gases, in accordance with ISO 17179:2016, or comparable methods.

The differential NOx technique using CL has been successfully tested on some power plants where the NOx concentration and NH3 concentration in flue gas after deNOx systems are up to 50 mg (NO)/m3 and 10 mg (NH3)/m3, respectively. AMS based on FTIR, NDIR with GFC and TLS has been used successfully in this application for measuring ranges as low as 10 mg (NH3)/m3.

Best Sellers From Chemical and Textile Sector

GSO 575:2016
 
Gulf Standard
Facial tissue - paper
GSO 2640:2021
 
Gulf Standard
Cosmetic Products - General Requirements of Soaps
GSO 1046:2021
 
Gulf Standard
Cosmetic Products - Perfumery Products based on Ethanol
GSO 2055-4:2021
 
Gulf Standard
Halal Products- Part 4: Requirements for Halal Cosmetics and Personal care

Recently Published from Chemical and Textile Sector

GSO 2528:2024
 
Gulf Technical Regulation
Cosmetic products – Technical Regulation of Cosmetic and Personal Care Products Claims
GSO 1943:2024
 
Gulf Technical Regulation
Cosmetic Products – Safety Requirements of Cosmetics and Personal Care Products
GSO ISO 11357-8:2024
ISO 11357-8:2021 
Gulf Standard
Plastics — Differential scanning calorimetry (DSC) — Part 8: Determination of thermal conductivity
GSO ISO/TR 23383:2024
ISO/TR 23383:2020 
Gulf Standard
Textiles and textile products — Smart (Intelligent) textiles— Definitions, categorisation, applications and standardization needs